AFNI program: align_epi_anat.py

Output of -help


#++ align_epi_anat version: 1.63

    ===========================================================================
    align_epi_anat.py     - align EPI to anatomical datasets or vice versa
    
    This Python script computes the alignment between two datasets, typically
    an EPI and an anatomical structural dataset, and applies the resulting
    transformation to one or the other to bring them into alignment.

    This script computes the transforms needed to align EPI and  
    anatomical datasets using a cost function designed for this purpose. The  
    script combines multiple transformations, thereby minimizing the amount of 
    interpolation applied to the data.
    
    Basic Usage:
      align_epi_anat.py -anat anat+orig -epi epi+orig -epi_base 5
    
    The user must provide EPI and anatomical datasets and specify the EPI
    sub-brick to use as a base in the alignment.  

    Internally, the script always aligns the anatomical to the EPI dataset,
    and the resulting transformation is saved to a 1D file. 
    As a user option, the inverse of this transformation may be applied to the 
    EPI dataset in order to align it to the anatomical data instead.

    This program generates several kinds of output in the form of datasets
    and transformation matrices which can be applied to other datasets if
    needed. Time-series volume registration, oblique data transformations and
    Talairach (standard template) transformations will be combined as needed
    and requested (with options to turn on and off each of the steps) in
    order to create the aligned datasets.
    
    **Note the intermediate datasets used to compute the alignment are **not**
    saved unless one of the -save_xxx options is given. This includes
    skull-stripped, slice timing corrected and volume registered datasets
    without alignment. These intermediated datasets are normally deleted.
    See the -save_xxx section below for more information on saving these 
    datasets for future use.
    
    Depending upon selected options, the script's output contains the following:
        Datasets:
          ANAT_al+orig: A version of the anatomy that is aligned to the EPI
          EPI_al+orig: A version of the EPI dataset aligned to the anatomy
          EPI_tlrc_al+tlrc: A version of the EPI dataset aligned to a standard
                       template
        These transformations include slice timing correction and
          time-series registration by default.

        Transformation matrices:
          ANAT_al_mat.aff12.1D: matrix to align anatomy to the EPI
          EPI_al_mat.aff12.1D:  matrix to align EPI to anatomy 
                                   (inverse of above)
          EPI_vr_al_mat.aff12.1D: matrix to volume register EPI
          EPI_reg_al_mat.aff12.1D: matrix to volume register and align epi
                                   to anatomy (combination of the two
                                   previous matrices)
          EPI_al_tlrc_mat.aff12.1D: matrix to volume register and align epi
                                   to anatomy and put into standard space

        Motion parameters from optional volume registration:
          EPI_tsh_vr_motion.1D: motion parameters from EPI time-series 
                                registration (tsh included in name if slice
                                timing correction is also included).
          
    where the uppercase "ANAT" and "EPI" are replaced by the prefix names
    of the input datasets, and the suffix can be changed from "_al" as a user
    option.
          
    You can use these transformation matrices later to align other datasets:
         3dAllineate -cubic -1Dmatrix_apply epi_r1_al_mat.aff12.1D  \
                     -prefix epi_alman epi_r2+orig

             
    The goodness of the alignment should always be assessed visually.
    Superficially, most of 3dAllineate's cost functions, and those
    of registration programs from other packages, will produce a plausible
    alignment based upon a cursory examination but it may not be the best.
    You need to examine the results carefully if alignment quality is crucial
    for your analysis.

    In the absence of a gold standard, and given the low contrast of EPI data,
    it is difficult to judge alignment quality by just looking at the two
    volumes. This is the case, even when you toggle quickly between one volume
    and the next, by turning the color overlay off and using the 'u' key in the
    slice viewer window. To aid with the assessment of alignment, you can use
    the -AddEdge option or call the @AddEdge script directly. See the help for
    @AddEdge for more information on that script.

    The default options assume the epi and anat datasets start off fairly close,
    as is normally the case when the epi dataset closely precedes or follows an 
    anatomical dataset acquisition. If the two data are acquired over separate
    sessions, or accurate coordinate data is not available in the dataset header
    (as sometimes occurs for oblique data), various options allow for larger
    movement including "-cmass cmass", "-big_move","-giant_move",
    "-ginormous_move", and -align_centers yes". Each of these options
    is described below. If the datasets do not share the same
    coordinate space at all, it may be useful to use the "-ginormous_move", 
    "-align_centers" options or run @Align_Centers script first.
    
    Although this script has been developed primarily for aligning anatomical T1
    data with EPI BOLD data, it has also been successfully applied for aligning
    similar modality data together, including T1-SPGR to T1-SPGR, T1-FLAIR
    to T1-SPGR, EPI to EPI, T1-SPGR at 7T to T1-SPGR at 3T, EPI-rat1 to
    EPI-rat2, .... If this kind of alignment is required, the default cost
    function, the Local Pearson Correlation (lpc), is not appropriate.
    Other cost functions like lpa or nmi have been seen to work well for
    intra-modality alignment, using the option "-cost lpa". Also see the the
    dset1 and dset2 options below for functionally equivalent options to the
    epi and anat options.
        
    ---------------------------------------------
    REQUIRED OPTIONS:
    
    -epi dset   : name of EPI dataset
    -anat dset  : name of structural dataset
    -epi_base   : the epi base used in alignment 
                     (0/mean/median/max/subbrick#)

    MAJOR OPTIONS:
    -help       : this help message

    -anat2epi   : align anatomical to EPI dataset (default)
    -epi2anat   : align EPI to anatomical dataset

    The following options are equivalent to those epi/anat options above
    except it is assumed the datasets will have similar modalities if
    either dset1 or dset2 is specified, and the default cost function is
    changed to 'lpa' instead of 'lpc'. This should reduce confusion when
    aligning other types of datasets. Most other options that also have
    names with anat and epi have corresponding dset1 and dset2 options
    that are exactly equivalent.

    -dset1      : name of dataset1
    -dset2      : name of dataset2
    -dset1to2   : align dataset1 to dataset2
    -dset2to1   : align dataset2 to dataset1
    

    -suffix ssss: append suffix 'sss' to the original anat/epi dataset to use
                     in the resulting dataset names (default is "_al")
     
    -child_epi dset1 dset2 ... : specify other EPI datasets to align.
        Time series volume registration will be done to the same
        base as the main parent EPI dataset. 
        Note if aligning anat to epi, you can still use the -save_vr option
        to save the volume registered (motion corrected) datasets. See the 
        -save_xxx option section of this help for more information.
    -child_dset2  equivalent to child_epi above

    -child_anat dset1 dset2 ... : specify other anatomical datasets to align.
        The same transformation that is computed for the parent anatomical
        dataset is applied to each of the child datasets. This only makes
        sense for anat2epi transformations. Skullstripping is not done for
        the child anatomical dataset.
    -child_dset1  equivalent to child_anat above

    -AddEdge    : run @AddEdge script to create composite edge images of
                  the base epi or anat dataset, the pre-aligned dataset and 
                  the aligned dataset. Datasets are placed in a separate
                  directory named AddEdge. The @AddEdge can then be used
                  without options to drive AFNI to show the epi and anat
                  datasets with the edges enhanced. For the -anat2epi case
                  (the default), the anat edges are shown in purple, and the
                  epi edges are shown in cyan (light blue). For the -epi2anat
                  case, the anat edges are shown in cyan, and the epi edges
                  are purple. For both cases, overlapping edges are shown in
                  dark purple.

    -big_move   : indicates that large displacement is needed to align the
                  two volumes. This option is off by default.
    -giant_move : even larger movement required - uses cmass, two passes and
                  very large angles and shifts. May miss finding the solution
                  in the vastness of space, so use with caution
    -ginormous_move : adds align_centers to giant_move. Useful for very far
                  apart datasets

    Notes on the big_move and giant_move options:
        "big_move" allows for a two pass alignment in 3dAllineate.
        The two-pass method is less likely to find a false minimum 
        cost for alignment because it does a number of coarse (blurred,
        rigid body) alignments first and then follows the best of these
        coarse alignments to the fine alignment stage. The big_move 
        option should be a relatively safe option, but it adds
        processing time.

        The giant_move option expands the search parameters in space
        from 6 degrees and 10 mm to 45 degrees and 45 mm and adds in
        a center of mass adjustment. The giant_move option will usually
        work well too, but it adds significant time to the processing
        and allows for the possibility of a very bad alignment.Another cost
        functional is available that has worked well with noisy data, "lpc+ZZ".
        For difficult data, consider that alternative.

        If your data starts out fairly close (probably the typical case
        for EPI and anatomical data), you can use the -big_move with 
        little problem. All these methods when used with the default
        lpc cost function require good contrast in the EPI image so that
        the CSF can be roughly identifiable.

    -rigid_body   Limit transformation to translation and rotation,
                  no scaling or shearing.
    -rigid_equiv  Compute alignment with full affine 12 parameters, but
                  use only the translation and rotation parameters. Useful
                  for axialization/AC-PC alignment to a template 
   
    -partial_coverage: indicates that the EPI dataset covers only a part of 
                  the brain. Alignment will try to guess which direction should
                  not be shifted If EPI slices are known to be a specific 
                  orientation, use one of these other partial_xxxx options.
    -partial_axial
    -partial_coronal 
    -partial_sagittal

    -keep_rm_files : keep all temporary files (default is to remove them)
    -prep_only  : do preprocessing steps only
    -verb nn    : provide verbose messages during processing (default is 0)
    -anat_has_skull yes/no: Anat is assumed to have skull ([yes]/no)
    -epi_strip methodname :  method to mask brain in EPI data 
                   ([3dSkullStrip]/3dAutomask/None)
    -volreg_method methodname: method to do time series volume registration
                   (motion correction) of EPI data 
                   ([3dvolreg],3dWarpDrive,3dAllineate). 
                   3dvolreg is for 6 parameter (rigid-body)
                   3dWarpDrive is for 12 parameter (general affine)
                   3dAllineate - also 12 parameter with LPA cost function

                   Note if aligning anat to epi, the volume registered EPI
                   dataset is **not** saved unless you use the -save_vr
                   option. See the -save_xxx option section of this help for
                   more information.

    -dset1_strip : skull stripping method for dataset1 
    -dset2_strip : skull stripping method for dataset2 (equivalent to epi_strip)

    A template registered anatomical dataset such as a talairach-transformed
       dataset may be additionally specified so that output data are
       in template space. The advantage of specifying this transform here is
       that all transformations are applied simultaneously, thereby minimizing 
       data interpolation.
       
    -tlrc_apar ANAT+tlrc : structural dataset that has been aligned to
                  a master template such as a tlrc dataset. If this option
                  is supplied, then an epi+tlrc dataset will be created. 
                  The @auto_tlrc script may be used to create this 
                  "talairach anatomical parent". This option is only valid
                  if aligning epi to anat.


    Other options:
    -ex_mode modename : execute mode (echo/dry_run/quiet/[script]).
                     "dry_run" can be used to show the commands that
                     would be executed without actually running them. 
                     "echo" shows the commands as they are executed.
                     "quiet" doesn't display commands at all.
                     "script" is like echo but doesn't show stdout, stderr 
                     header lines and "cd" lines.
                     "dry_run" can be used to generate scripts which can be
                     further customized beyond what may be available through
                     the options of this program.
    -Allineate_opts '-ssss  -sss' : options to use with 3dAllineate. Default
                     options are 
                     "-weight_frac 1.0 -maxrot 6 -maxshf 10 -VERB -warp aff "
    -volreg [on]/off : do volume registration on EPI dataset before alignment
    -volreg_opts  '-ssss -sss' : options to use with 3dvolreg
    -volreg_base basenum/type : the epi base used in time series volume
                     registration.
                     The default is to use the same base as the epi_base.
                     If another subbrick or base type is used, an additional
                     transformation will be computed between the volume
                     registration and the epi_base
                     (0/mean/median/max/subbrick#)
                     
                     Note if aligning anat to epi, the volume registered EPI
                     dataset is **not** saved unless you use the -save_vr
                     option. See the -save_xxx option section of this help for
                     more information.

    -tshift [on]/off : do time shifting of EPI dataset before alignment
    -tshift_opts   : options to use with 3dTshift
                     The script will determine if slice timing correction is
                     necessary unless tshift is set to off.

    -deoblique [on]/off : deoblique datasets before alignment
    -deoblique_opts '-ssss -sss': options to use with 3dWarp deobliquing
                     The script will try to determine if either EPI or anat data
                     is oblique and do the initial transformation to align anat
                     to epi data using the oblique transformation matrices
                     in the dataset headers.
    
    -master_epi  nnn : master grid resolution for aligned epi output
    -master_tlrc nnn : master grid resolution for epi+tlrc output
    -master_anat nnn : master grid resolution for aligned anatomical data output
    -master_dset1 nnn : equivalent to master_anat above
    -master_dset2 nnn : equivalent to master_epi above
                     (SOURCE/BASE/MIN_DXYZ/dsetname/n.nn)
                     Each of the 'master' options can be set to SOURCE,BASE,
                     a specific master dataset, MIN_DXYZ or a specified cubic 
                     voxel size in mm. 
                     
                     MIN_DXYZ uses the smallest voxel dimension as the basis
                     for cubic output voxel resolution within the bounding box
                     of the BASE dataset.
                     
                     SOURCE and BASE are used as in 3dAllineate help.
                     
                     The default value for master_epi and master_anat is SOURCE,
                     that is the output resolution and coordinates should be
                     the same as the input. This is appropriate for small
                     movements.
                   
                     For cases where either dataset is oblique (and larger
                     rotations can occur), the default becomes MIN_DXYZ.
                     
                     The default value for master_tlrc is MIN_DXYZ.
                     
                     "-master_dset1" and "-master_dset2" may be used as 
                     equivalent expressions for anat and epi output resolutions,
                     respectively.
                     
   -check_flip : check if data may have been left/right flipped by aligning
                     original and flipped versions and then comparing costs
                     between the two. This option produces the L/R flipped
                     and aligned anat/dset1 dataset. A warning is printed
                     if the flipped data has a lower cost function value
                     than the original dataset when both are aligned to the
                     epi/dset2 dataset.

                     This issue of left-right confusion can be caused
                     by problems with DICOM files or pipelines
                     that include Analyze format datasets. In these cases,
                     the orientation information is lost, and left-right may
                     be reversed. Other directions can also be confused, but
                     A-P and I-S are usually obvious. Note this problem has
                     appeared on several major publicly available databases.
                     Even if other software packages may proceed without errors
                     despite inconsistent, wrong or even missing coordinate
                     and orientation information, this problem can be easily
                     identified with this option.

                     This option does not identify which of the two datasets
                     need to be flipped. It only determines there is likely 
                     to be a problem with one or the other of the two input
                     datasets. Importantly, we recommend properly visualizing
                     the datasets in the afni GUI. Look for asymmetries in the
                     two aligned anat/dset1 datasets, and see how they align
                     with the epi/dset2 dataset. To better determine the left
                     and right of each dataset, we recommend relying on tags
                     like vitamin E or looking for surgical markers.
                      
   -flip_giant : apply giant_move options to flipped dataset alignment
                     even if not using that option for original dataset
                     alignment

   -save_xxx options
      Normally all intermediate datasets are deleted at the end of the script.
      If aligning anat to epi, the volume registered EPI dataset, although
      computed, is **not** saved unless you use the -save_vr option.
      Similarly other intermediate datasets are not saved unless explicitly
      requested with one of these options:
      -save_Al_in       : save 3dAllineate input files
      -save_tsh         : save tshifted epi
      -save_vr          : save volume registered epi
      -save_skullstrip  : save skull-stripped (not aligned)
      -save_rep         : save representative tstat epi
      -save_resample    : save resampled epi
      -save_epi_ns      : save skull-stripped epi
      -save_all         : save all the above datasets

      Not included with -save_all (since parameters are required):

      -save_orig_skullstrip PREFIX : save original skull-stripped dset
      -save_script SCRIPT_NAME     : save shell command script to given file

   Alternative cost functions and methods:
     The default method used in this script is the LPC (Localized Pearson 
     Correlation) function. The 'lpc' cost function is computed by the
     3dAllineate program. Other cost functionals are available and are
     described briefly in the help for 3dAllineate. This script allows
     the user to choose any cost function available in that program with
     
     -cost xxx
     
     Some cost functionals have proven to be useful for some situations.
     Briefly, when aligning similar datasets (anat to anat), the 'lpa' method
     usually provides good alignment. Instead of using a negative correlation,
     as the 'lpc' method does, the 'lpa' cost functional uses the absolute value
     of the local correlation, so both positive and negative correlations drive
     the alignment. Occasionally the simplest least squares cost functional
     will be useful (implemented with -ls).
     
     If either of the input datasets has very little structural detail (less
     than typical EPI), the mutual information methods provide a rough
     alignment that gives alignment of mostly the contour of the datasets.
     These are implemented with '-cost nmi' or '-cost mi'. 
     
     The lpa cost function looks for both high positive and negative 
     local Pearson correlation (LPA is an acronym in our program for the
     absolute value of the local Pearson correlation). The LPC method looks
     for negative correlation, essentially matching the dark CSF in T1 images
     with the bright CSF in EPI images. The more negative the correlation the
     more likely the CSF will overlay each other and carry the rest of the 
     volume along with it.
     
     -multi_cost cf1 cf2 ...
     Besides cost from specified cost function or default cost function,
     also compute alignment using other cost functionals. For example, using
     "-cost lpa -multi_cost ls nmi" will compute an alignment for the lpa, ls
     and nmi cost functionals. See 3dAllineate's HELP for a full list of
     available cost functionals. Use the AFNI GUI to view differences among
     cost functionals.

     -check_cost cf1 cf2 ...
     Verify alignment against another cost functional. If there is a large
     difference, a warning is printed. This does not mean the alignment is
     bad, only that it is different.
     
     -edge       :  use edge method
     
     The Edge method
     Finally, the "edge" method is a new method that is implemented not as a
     cost functional but as a different algorithm altogether. Based on our
     visualization methods for verifying alignment (as we do in AddEdge),
     it uses a local approach like the LPA/C cost functionals, but it is
     independent of the cost function. 
     
     This method has turned out to be useful in a variety of circumstances. It
     has proven useful for data that changes dramatically over time like
     manganese-enhanced MRI (MEMRI) and for some data that has other large
     non-uniformities issues helping to compensate for those large contrasts.
     
     The edge method prepares the image to be a local spatial variance version
     of the original image. First both input datasets are automasked with the 
     outer voxel layers removed. The spatial variance is computed over that
     mask. The optimal alignment is computed between the edge images. Strictly
     speaking, the datasets are not "edges" but a kind of normalized 2D
     gradient. The original datasets are then aligned using the transformation
     computed by the edge image alignment. Internally within the script,
     the gradient function is accomplished by the 3dLocalstat program using its
     cvar option for coefficient of variation. The coefficient of variation is
     computed as the standard deviation within the local neighborhood divided
     by the mean. The local spatial variance ends up being similar to locally
     normalized images of edges within the image. 
     
     The "-edge" option is relatively insensitive to most of the cost functions
     in 3dAllineate, so "lpa", "mi", "nmi" and even "ls" will usually work well.
     The default is to use the lpa cost functional together with the edge
     method.

     The edge image is different in a couple ways from the LPA/C correlation.
     First it is a different function, essentially only a standard deviation
     over a neighborhood, and then normalized by the absolute value of the
     mean - effectively a spatial variance (or square root of the variance).
     The second difference is that while the LPA/C cost functions also operates
     on local neighborhoods, those neighborhoods are 3-dimensional and set by
     a neighborhood size set in mm. The shape of the neighborhoods are
     dodecahedrons (12-side figures) that cover the volume. The edge method
     instead computes the neighborhoods at each voxel, and the neighborhoods
     are only two-dimensional - just the voxel and its 8 neighbors in x and y,
     presumed to be in the same slice rather than across slices. That's for
     both speed in computation and to remove effects of interpolation or false
     edges across the relatively distant slices.

     Although not as rigorously tested as the LPC method, this edge method
     seems to give similar results most of the time. The method does have a few
     disadvantages compared to the LPC/LPA methods. First, the AddEdge
     visualization in this script does not support this well (effectively,
     showing edges of edges). Second, the edge method does not provide
     three-dimensional edge detection directly. Many times this is an advantage,
     but if the data has particularly fine slicing in the z-direction, or the
     data has been resampled, this method may not work as well. Also the method
     uses an automask to reduce the data so that outside edges do not drive
     the alignment. The five voxel layer was only empirically found to be
     useful for this, but may, in fact, be problematic for small partial volumes
     or for surface coil data where much of the data may be in the area that
     is masked away.
     
     The edge method makes no assumption about contrasts between images. Only
     that edges of features will overlap - the same feature we use visually to
     verify alignment. This makes it appropriate for both similar and differing
     modality datasets.
     
     Both the LPA/LPC and the edge methods require internal features to be
     present and mostly corresponding in both input datasets. In some cases,
     this correspondence is not available for aligning some kinds of data with
     an anatomical references - low-contrast EPI data, radiopharmaceutical PET
     data targeting specific function, derived parameters from modeling.
     In these cases, fine alignment is not possible, but alternative cost
     functions like mutual information or least squares can provide a rough
     alignment of the contours.

     -output_dir dirname : the default output will put the result in
     the current directory even if the anat and epi datasets are in other 
     directories. If a directory is specified here, output data including
     temporary output data will be placed in that directory. If a new directory 
     is specified, that directory will be created first.
     
    Other obscure and experimental options that should only be handled with 
       care, lest they get out, are visible with -option_help.

    Examples:
      # align anat to sub-brick 5 of epi+orig. In addition, do slice timing
      # correction on epi+orig and register all sub-bricks to sub-brick 5
      # (Sample data files are in AFNI_data4/sb23 in sample class data)
      # Note the intermediate file, the volume registered EPI dataset,
      # is **not** saved unless the -save_vr option is also used.
      # See the -save_xxx option section of this help for more information.

      align_epi_anat.py -anat sb23_mpra+orig -epi epi_r03+orig     \
                        -epi_base 5
      
      # Instead of aligning the anatomy to an epi, transform the epi
      # to match the anatomy. Transform other epi run datasets to be
      # in alignment with the first epi datasets and with the anatomical
      # reference dataset. Note that all epi sub-bricks from all runs
      # are transformed only once in the process, combining volume
      # registration and alignment to the anatomical dataset in a single
      # transformation matrix

      align_epi_anat.py -anat sb23_mpra+orig -epi epi_r03+orig      \
                        -epi_base 5 -child_epi epi_r??+orig.HEAD    \
                        -epi2anat -suffix al2anat
      
      # Bells and whistles:
      # - create Talairach transformed epi datasets (still one transform)
      # - do not execute, just show the commands that would be executed.
      #   These commands can be saved in a script or modified.
      # The Talairach transformation requires auto-Talairaching 
      # the anatomical dataset first (cf. @auto_tlrc script)

      @auto_tlrc -base ~/abin/TT_N27+tlrc -input sb23_mpra+orig
      align_epi_anat.py -anat sb23_mpra+orig -epi epi_r03+orig      \
                        -epi_base 6 -child_epi epi_r??+orig.HEAD    \
                        -ex_mode dry_run -epi2anat -suffix _altest  \
                        -tlrc_apar sb23_mpra_at+tlrc


    Our HBM 2008 abstract describing the alignment tools is available here:
      https://sscc.nimh.nih.gov/sscc/rwcox/abstracts
    
    Reference:
       If you find the EPI to Anat alignment capability useful, the paper to
       cite is:
       
       ZS Saad, DR Glen, G Chen, MS Beauchamp, R Desai and RW Cox.
       A new method for improving functional-to-structural alignment using
       local Pearson correlation. NeuroImage, 44:839-848, 2009.
       http://dx.doi.org/10.1016/j.neuroimage.2008.09.037


A full list of options for align_epi_anat.py:

   -epi                
      use:                EPI dataset to align or to which to align
   -dset2              
      use:                dataset to align or to which to align
   -anat               
      use:                Anatomical dataset to align or to which to align
   -dset1              
      use:                Dataset to align or to which to align
   -keep_rm_files      
      use:                Don't delete any of the temporary files created here
   -prep_only          
      use:                Do preprocessing steps only without alignment
   -help               
      use:                The main help describing this program with options
   -limited_help       
      use:                The main help without all available options
   -option_help        
      use:                Help for all available options
   -version            
      use:                Show version number and exit
   -ver                
      use:                Show version number and exit
   -verb               
      use:                Be verbose in messages and options
   -save_script        
      use:                save executed script in given file
   -align_centers      
      use:                align centers of datasets based on spatial
                          extents of the original volume
      allowed:            yes, no, on, off
      default:            no
   -anat_has_skull     
      use:                Do not skullstrip anat dataset
      allowed:            yes, no
   -epi_strip          
      use:                Method to remove skull for EPI data
      allowed:            3dSkullStrip3dAutomask, None
   -dset1_strip        
      use:                Method to remove skull for dset1 data
      allowed:            3dSkullStrip, 3dAutomask, None
   -dset2_strip        
      use:                Method to remove skull for dset2 data
      allowed:            3dSkullStrip, 3dAutomask, None
   -volreg_method      
      use:                Time series volume registration method
                          3dvolreg: rigid body least squares
                          3dWarpDrive: 12 parameter least squares
                          3dAllineate: 12 parameter LPA cost function
                          
      allowed:            3dvolreg, 3dWarpDrive, 3dAllineate
      default:            3dvolreg
   -ex_mode            
      use:                Command execution mode.
                          quiet: execute commands quietly
                          echo: echo commands executed
                          dry_run: only echo commands
                          
      allowed:            quiet, echo, dry_run, script
      default:            script
   -overwrite          
      use:                Overwrite existing files
   -big_move           
      use:                Large movement between epi and anat.
                          Uses twopass option for 3dAllineate.
                          Consider cmass options, giant_move,
                          ginormous_move or -align_centers
   -giant_move         
      use:                Even larger movement between epi and anat.
                          Uses twopass option for 3dAllineate.
                          cmass options and wide angles and shifts
   -ginormous_move     
      use:                Adds align_centers to giant_move
   -supersize          
      use:                Large scaling difference - up to 50%
   -rigid_body         
      use:                Do only rigid body alignment - shifts and rotates
   -rigid_equiv        
      use:                Do only rigid body equivalent alignment - shifts and rotates
   -partial_coverage   
      use:                partial_xxxx options control center of mass adjustment
   -partial_axial      
   -partial_coronal    
   -partial_sagittal   
   -AddEdge            
      use:                Run @AddEdge script to create double-edge images
   -Allineate_opts     
      use:                Options passed to 3dAllineate.
      default:            -weight_frac 1.0 -maxrot 6 -maxshf 10 -VERB -warp aff -source_automask+4 
   -perc               
      default:            90
   -suffix             
      default:            _al
   -cost               
   -multi_cost         
      use:                can use multiple cost functionals (lpc,lpa,nmi,....
                          See 3dAllineate -HELP for the full list
                          
   -check_cost         
      use:                Verify alignment against another method
                          Can use multiple cost functionals (lpc,lpa,nmi,....
                          See 3dAllineate -HELP for the full list
                          
   -epi2anat           
      use:                align EPI dataset to anat dataset
   -anat2epi           
      use:                align anat dataset to EPI dataset (default)
   -dset2to1           
      use:                align dset2 dataset to dset1 dataset
   -dset1to2           
      use:                align dset1 dataset to dset2 dataset (default)
   -epi_base           
      use:                Base sub-brick to use for alignment
                          Choose sub-brick number or statistic type
                          Valid choices can be, for example, 0,5,mean
   -dset2_base         
      use:                Base sub-brick to use for alignment
                          Choose sub-brick number or statistic type
                          Valid choices can be, for example, 0,5,mean
   -volreg_base        
      use:                Base to use for volume registration
                          Choose sub-brick number or statistic type
                          Valid choices can be, for example, 0,5,median
   -volreg             
      allowed:            on, off
   -volreg_opts        
      default:            -cubic
   -tshift             
      allowed:            on, off
   -tshift_opts        
   -deoblique          
      allowed:            on, off
   -deoblique_opts     
   -resample           
      allowed:            on, off
   -prep_off           
      use:                turn off all pre-processing steps including
                          deoblique, tshift, volreg and resample
   -cmass              
      use:                choose center of mass options for 3dAllineate
                          Center of mass shifts the center of the datasets to match
                          by computing the weighted centers of each.
                          For partial data, this may be too far in one direction
                          See 3dAllineate help for details
                          Valid options include cmass+a, cmass+xy, nocmass
                          nocmass = no center of mass shift - default
                          cmass = center of mass shift - used with giant, ginormous_move
                          cmass+a = automatic center of mass for partial data
                          cmass+xy,xz,yz = automatic center of mass for partial
                                           axial,coronal,sagittal
                          For partial data, it may be easier to select one
                           of the partial_... options above
   -tlrc_apar          
      use:                If this is set, the results will include +tlrc
                          template transformed datasets for the epi aligned
                          to the anatomical combined with this additional
                          transformation to template of this parent dataset
                          The result will be EPI_al+tlrc.HEAD
                          
   -tlrc_epar          
      use:                Not available yet.
                          If this is set, the results will include +tlrc
                          template transformed datasets for the anatomical
                          aligned to the epi combined with this additional
                          transformation to template of this parent dataset
                          The result will be ANAT_al+tlrc.HEAD
                          
   -auto_tlrc          
      use:                Not available yet.
                          If this is set, the results will also be aligned
                          to a template using the @auto_tlrc script.
                          Transformations computed from that will be combined
                          with the anat to epi transformations and epi to anat
                          (and volreg) transformations
                          Only one of the -tlrc_apar, -tlrc_epar or the 
                          -auto_tlrc options may be used
                          
   -child_epi          
      use:                Names of child EPI datasets
   -child_dset2        
      use:                Names of children of dset2 datasets
   -child_anat         
      use:                Names of child anatomical datasets
   -child_dset1        
      use:                Names of children of dset1 datasets
   -master_epi         
      use:                -master grid resolution for epi to anat alignment
                          MIN_DXYZ uses the smallest dimension
                          Other options are SOURCE and BASE as in 3dAllineate
                          help. For cases where either dataset is oblique, the
                          default becomes MIN_DXYZ
   -master_dset2       
      use:                -master grid resolution for epi to anat alignment
                          MIN_DXYZ uses the smallest dimension
                          Other options are SOURCE and BASE as in 3dAllineate
                          help. For cases where either dataset is oblique, the
                          default becomes MIN_DXYZ
   -master_tlrc        
      use:                -master grid resolution for epi to tlrc anat
                          alignment
                          MIN_DXYZ uses the smallest dimension
                          Other options are SOURCE and BASE as in 3dAllineate
                          help
   -master_anat        
      use:                -master grid resolution for anat to epi output
                          MIN_DXYZ uses the smallest dimension
                          Other options are SOURCE, BASE, 'n' mm or gridset
   -master_dset1       
      use:                -master grid resolution for dset1 to dset2 output
                          MIN_DXYZ uses the smallest dimension
                          Other options are SOURCE, BASE, 'n' mm or gridset
   -master_anat_dxyz   
      use:                -master grid resolution size (cubic only)
                          
   -master_dset1_dxyz  
      use:                -master grid resolution size (cubic only)
                          
   -master_epi_dxyz    
      use:                -master grid resolution (cubic only)
                          
   -master_dset2_dxyz  
      use:                -master grid resolution (cubic only)
                          
   -master_tlrc_dxyz   
      use:                -master grid resolution (cubic only)
                          
   -pre_matrix         
      use:                Apply an initial transformation from a 1D file (NB:
                          not from a *.aff12.1D file); the *.1D file should
                          contain a 3x4 matrix of numbers.
                          For example, this file may be one generated by 
                          @Align_Centers, or if inverting a matrix, with:
                            cat_matvec mat.aff12.1D -I > mat_INV.1D
                          The transformation will be applied to the
                          anatomical data before aligning to the EPI
                          instead of using the built-in obliquity matrices,
                          if any
   -post_matrix        
      use:                Apply an additional transformation from a 1D file.
                          This transformation will be applied to the anatomical
                          data after alignment with the EPI. This will be
                          applied similarly to the tlrc transformation and in
                          place of it.
                          Output datasets are kept in the 'orig' view
   -skullstrip_opts    
      use:                Alternate options for 3dSkullstrip.
                          like -rat or -blur_fwhm 2
   -dset1strip_opts    
      use:                Alternate name for skullstrip_opts
   -epistrip_opts      
      use:                Alternate options for 3dSkullstrip/3dAutomask.
                          like -rat or -blur_fwhm 2 or -peels 2
   -dset2strip_opts    
      use:                Alternate name for epistrip_opts
   -feature_size       
      use:                Minimal size in mm of structures in images to match.
                          Changes options for 3dAllineate for the coarse
                          blurring and lpc/lpa neighborhood sizes.May be useful
                          for rat brains, anat to anat and other
                          'non-standard' alignment
   -rat_align          
      use:                Set options appropriate for rat data - 
                          namely skullstrip and feature size options above.
                          
   -output_dir         
      use:                Set directory for output datasets
                          
   -edge               
      use:                Use internal edges to do alignment
   -edge_erodelevel    
      use:                Number of layers to remove for edge method
   -check_flip         
      use:                Check if L/R flipping gives better results
   -flip_giant         
      use:                use giant_move on flipped data even if not used
                          on original data
   -save_Al_in         
      use:                Save datasets used as input to 3dAllineate
   -save_vr            
      use:                Save motion-corrected epi dataset
   -save_tsh           
      use:                Save time-series corrected dataset
   -save_skullstrip    
      use:                Save unaligned, skullstripped dataset
   -save_orig_skullstrip
      use:                Save simply skullstripped dataset
   -save_epi_ns        
      use:                Save unaligned, skullstripped EPI dataset
   -save_rep           
      use:                Save unaligned representative tstat EPI dataset
   -save_resample      
      use:                Save unaligned EPI dataset resampled to anat grid
   -save_all           
      use:                Save all optional datasets
   -pow_mask           
      use:                power for weighting 1 or 2
      default:            1.0
   -bin_mask           
      use:                convert weighting mask to 0 or 1 - Unused
      allowed:            yes, no
      default:            no
   -box_mask           
      use:                Unused
      allowed:            yes, no
      default:            no
   -mask               
      use:                Not available yet.
                          Mask to apply to data.
      default:            vent


This page auto-generated on Tue Dec 17 06:54:12 PM EST 2024